Thank you for your vested interest in part number APS-064, one of the many Transformerpower items we offer from Magnetika Inc. On this page, you can easily fill out a Request for Quote (RFQ) form for NSN 5950004954663 that caters to your requirements. Simply fill out the form below with details about your situation, such as desired part quantity and expected shipping deadline, and a dedicated account manager will reach out to you with a competitive quote for your comparisons in 15 minutes or less. For more information, you are also welcome to contact us at any time via phone or email, as we are available around the clock!
Note : We Will Not Share Your Information To Any Third Parties.
Aside from the NSN 5950-00-495-4663, we carry a host of other parts within the Federal Supply Class 5950 Coils and Transformers. Each of these items are fully traceable and have been sourced from credible manufacturers whom we trust, including Magnetika Inc with the CAGE Code 15634. Additionally, you can count on us for quality-evaluated products that come delivered with their qualifying certifications and manufacturer trace documentation, as applicable. Regardless of your situation, NSN Matrix is here to assist you with all the logistics behind part procurement, so kick off the purchasing process with us today to learn how we can get you the parts your operations require ASAP!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-495-4663 Item PartTypeName: TRANSFORMER,POWER | 5950 | 004954663 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
890827 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.060 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.060 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.060 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.250 INCHES NOMINAL4.250 INCHES NOMINAL4.250 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.950 INCHES NOMINAL2.950 INCHES NOMINAL2.950 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.370 INCHES NOMINAL2.370 INCHES NOMINAL2.370 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AGAV | END ITEM IDENTIFICATION | WSD: AIRCRAFT,PHANTOM F-4 |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 8 SECONDARY SINGLE COMPONENT8 SECONDARY SINGLE COMPONENT8 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP32 SINGLE GROUP32 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 178.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 189.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 310.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 22.0 WATTS SINGLE COMPONENT SINGLE PRIMARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 17.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY188.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY17.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 31.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 31.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY17.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY31.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.90 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.90 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY17.90 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY46.90 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | 5TH SECONDARY 10.5V 118 MA,6TH SEC 10.5V 275 MA,7TH SEC 71.0V 1.5A,8TH SEC 77.5V 1.68A; WEAPON SYSTEM ESSENTIAL |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 27 PIN |